K11020 VisionSensor™ 2030 User Manual, Rev. E, Software ver. 3.1.1000, August 3, 2007 - 45
Save Settings
5.2 - Set Targeting Zone Tolerances
50 Most Accurate 75 100 125
150 200 400 1600 (Default)
Least Accurate
The targeting zone is the area around the outside of the code that is viewed by the imager. The values
of each of the following codes are the pixels extending from the outside of the edge of the symbol being
scanned. As the targeting zone becomes smaller the targeting laser must be more centered in the sym-
bol being scanned. Conversely, as the targeting area outside the code gets larger there is less precision
needed with the targeting laser. There is also a greater chance the imager will have more than one code in
the eld of view. The symbol in focus, closest to the targeting laser will be decoded.
5.1 - Continuous Illumination
Scan one of the following codes to enable continuous LED illumination.
Enable Continuous Illumination Disable Continuous Illumination (Default)
Note: Videk recommends only using this feature with cabled units due to increased power consumption.